Atmosphères des lieux de travail – Partie 1: Détecteurs de gaz – Exigences d'aptitude à la fonction des détecteurs de gaz toxiques

Numéro de référence:
CSA C22.2 NO. 62990-1
Catégorie de norme:
Norme nationale du Canada - Adoption d'une Norme internationale
Type d’activité d’élaboration de normes:
Nouvelle norme
Code ICS:
29.260.20
Statut:
En cours d'élaboration
Date de début de la période de commentaires OEN:
Date de fin de la période de commentaires des OEN:
Affiché le:

Porté:

Champ d’application

1    Scope

This part of ISO/IEC 62990 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications.

 

This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to  initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present.

 

This document applies to two types of equipment:

 

•             Type HM (Health Monitoring) ‘occupational exposure’ equipment:

For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1.

•             Type SM (Safety Monitoring) ‘general gas detection’ equipment:

For general gas detection applications (e.g. safety warning, leak detection),  the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment.

 

In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM.

 

For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour.

 

This document is not applicable to equipment:

 

–             with samplers and concentrators such as sorbents or paper tape having an irreversible indication;

–             used for the measurement of gases and vapours related to the risk of explosion;

–             used for the measurement of oxygen;

–             used only in laboratories for analysis or measurement;

–             used only for process measurement purposes;

–             used in the domestic environment;

–             used in environmental air pollution monitoring;

–             used for open-path (line of sight) area gas measurement;

–   used for ventilation control in car parks or tunnels.

 

Raison d’être du projet

Raison d’être du projet
To align Canadian requirements with those of international standards in the field of hazardous locations and to align with the Canadian Electrical Code, Part I.

Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.

Les OEN sont eux-mêmes responsables du contenu et de l’exactitude de l’information présentée ici. Cette information n’existe que dans la langue dans laquelle elle a été fournie au CCN.