Textiles — Quantitative analysis of cashmere, wool, other specialty animal fibres and their blends —...
This document specifies a method for the identification, qualitative, and quantitative analysis of cashmere, wool, other speciality animal fibres, and their blends using scanning electron microscopy (SEM).
It is applicable to loose fibres, intermediate products, and final products of cashmere, wool, other speciality animal fibres, and their blends.
Meat and meat products — Determination of moisture content — Reference method
This document specifies two reference methods for the determination of the moisture content of meat and meat products: a direct drying method and a distillation method.
The direct drying method is applicable to meat and meat products with low volatile substances in addition to moisture.
The distillation method is applicable to meat and meat products with high volatile substances in addition to…
Tractors and machinery for agriculture and forestry — Electrical high-power interface 700 V DC / 480...
This document describes the general safety requirements and guidance for the electrical high-power interface (HPI) in the ISO 23316 series.
The following topics are not within the scope of this document:
—    service, maintenance, and related diagnostics;
—    functional safety;
—    control strategies for high power supply systems (PS) and load consumption systems;
—    application-specific…
Tractors and machinery for agriculture and forestry — Electrical high-power interface 700 V DC / 480...
This document specifies required measures applicable to the HPI AC Interface between a supply system (typically located on an agricultural tractor) and detachable electrical consumer system (typically located on an agricultural implement).
This document covers the following:
—    HPI system topologies;
—    interface relevant characteristics of the HPI providing AC or combined AC and DC;
—    …
Radiological protection — Performance criteria for service laboratories performing biological dosime...
This document provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories using the dicentric assay performed with manual scoring.
This document is applicable to
a)Â Â Â the confidentiality of personal information, for the requestor and the service laboratory,
b)   the laboratory safety…
Power losses in voltage sourced converter (VSC) valves for high-voltage direct current (HVDC) system...
IEC 62751-2:2014+AMD1:2019+AMD2:2023 gives the detailed method to be adopted for calculating the power losses in the valves for an HVDC system based on the "modular multi-level converter", where each valve in the converter consists of a number of self-contained, two-terminal controllable voltage sources connected in series. It is applicable both for the cases where each modular cell…