STANDARD FOR INTERNAL LUG QUICK-CONNECT COUPLINGS FOR FIRE HOSE
1.1 This Standard contains requirements for non-threaded, quick-connect couplings
of the internal lug design for use in fire protection service. (See Appendix A.)
1.2 The couplings are intended for use with fire hose in the following standard sizes:
38 mm, 65 mm, 100 mm, 125 mm and 150 mm.
1.3 This Standard also contains requirements for the non-threaded, quick-connect
portion of adaptor…
NORME SUR LES RACCORDS RAPIDES À OREILLE INTERNE POUR TUYAUX D'INCENDIE
1.1 La présente norme énonce les exigences minimales applicables aux raccords
rapides non filetés à oreille interne pour les services de protection contre l'incendie. (Se reporter
à l'annexe A.)
1.2 Les raccords sont conçus pour les tuyaux d'incendie caractérisés par les
diamètres standard suivants : 38 mm, 65 mm, 100 mm, 125 mm et 150 mm.
1.3 La présente norme énonce…
Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the conne...
This National Standard of Canada is based on International Standard IEC/TR 61000-3-6:2008.
1 Scope
This Technical Report, which is informative in its nature, provides guidance on principles which can be used as the basis for determining the requirements for the connection of distorting installations to MV, HV and EHV public power systems (LV installations are covered in other IEC documents).…
LIVE WORKING - PORTABLE EQUIPMENT FOR GROUNDING AND BONDING
This National Standard of Canada is applicable to portable equipment, with or without matching connection points, for temporary earthing or earthing and short-circuiting of electrically isolated or de-energized a.c. and d.c. installations, transmission and distribution networks, whether they are overhead or underground or of low or high voltage. This standard covers equipment comprising an…
Fixed capacitors for use in electronic equipment - Part 14: Sectional specification: Fixed capacitor...
This National Standard of Canada is based on International Standard IEC 60384-14:2005.
Scope
This part of IEC 60384 applies to capacitors and resistor-capacitor combinations which will be connected to an a.c. mains or other supply with nominal voltage not exceeding 1 000 V a.c. (r.m.s.) or 1 000 V d.c. and with a nominal frequency not exceeding 100 Hz.
Scope
1.1.1 This Standard applies to service-entrance, feeder, and branch-circuit busways and associated fittings rated at 600 V or less, 6 000 A or less, and intended for use in accordance with the Canadian Electrical Code, Part I (CE Code, Part I), the National Electrical Code (NEC), NFPA 70, and the Mexican Standard for Electrical Installations (Utility), NOM-001-SEDE, (see Annex B,…
Information technology — Office equipment — Method for measuring digital printing productivity
ISO/IEC 24734:2009 provides a method for measuring the productivity of digital printing devices with various office applications and print job characteristics.
It is applicable to digital printing devices, including single function printing and multi-function devices, regardless of print technology (e.g. inkjet, laser). Devices can be equipped with a range of paper feed and finishing options…
Information technology - Office equipment - Method for measuring digital printing productivity
ISO/IEC 24734:2009 provides a method for measuring the productivity of digital printing devices with various office applications and print job characteristics.
It is applicable to digital printing devices, including single function printing and multi-function devices, regardless of print technology (e.g. inkjet, laser). Devices can be equipped with a range of paper feed and finishing options…
Installation couplers intended for permanent connection in fixed installations
IEC 61535:2009 applies to two up to five wire installation couplers including earth, if provided, with a rated voltage up to and including 500 V a.c. and a rated connecting capacity up to and including 10 mm² for permanent connection in indoor electrical installations. Installation couplers with additional contacts for voltages other than mains voltages are outside the scope of this standard. The…
Road vehicles — 50 ohms impedance radio frequency connection system interface — Part 2: Test procedu...
ISO 20860-2:2009 specifies the tests for male and female connectors of the 50 ohm impedance interface for radio frequency applications in road vehicles, and ensures communication to and within road vehicles.
These tests apply to all coaxial connectors for road vehicles with a 50 ohm radio frequency interface in accordance with ISO 20860-1.