Freight containers — Air/surface (intermodal) general purpose containers — Specification and tests
Lays down the basic requirements and the detailed design requirements. Annex B sets out the sections of other ISO-Standards which apply to this type of container. Requirements for containers to be transported by rotary-wing aircraft are excluded.
Specifies the method for determining the ability of metallic materials to undergo plastic deformation in bending. Applies to the bend test of test pieces taken from metallic products as specified in the relevant product standards. It is not applicable to certain materials and/or products, for example tubes in full section or welded joints, for which other standards exist.
Asphalt Shingle Application on Roof Slopes 1:6 to Less Than 1:3
1. Scope
1.1
This Standard describes the minimum application requirements for asphalt strip shingles or low slope shingles on roofs with slopes from 1:6 to less than 1:3.
Note: Roof Substrate and Ventilation Below Substrate. Appendix A is included to provide recommendations for acceptable substrate for shingles; Appendix B, recommendations for acceptable ventilation below the shingle…
Asphalt Shingle Application on Roof Slopes 1:3 and Steeper
1. Scope
1.1
This Standard describes the minimum application requirements for asphalt strip shingles on roofs with slopes 1:3 and steeper.
Note: Roof Substrate and Ventilation Below Substrate. Appendix A is included to provide recommendations for acceptable substrate for shingles; Appendix B, recommendations for a cceptable ventilation below the shingle substrate; and Appendix C,…
Prescribes the minimum design requirements applicable to
construction of overhead electric supply and communication lines
located entirely outside of buildings and fenced supply stations.
It includes electric supply and communication circuits installed
alone, in joint use or in proximity to each other or other
facilities; crossing each other or other facilities, including
railways or…
1. Scope
1.1 This Standard applies to thermal cut-offs (TCO) for voltages up to and including 600 V, intended for the protection of equipment such as electric motors, transformers, fluorescent lighting ballasts, and electric heating appliances to be used indoors in accordance with the Rules of the Canadian Electrical Code, Part I. Notes: (1) Thermal cut-offs function once only and are used for…
Circulating Tank Instantaneous and Large Automatic Storage Type Gas Water
Heaters
Covers the construction and performance of automatic storage type
water heaters having input ratings ranging from 75 000 to 400 000
Btuh, instantaneous water heaters, and circulating type water
heaters. The standard also applies to instantaneous water heaters
for installation in mobile housing and recreational vehicles
1. Scope
1.1 This method of test is applicable to firestop systems incorporating through
penetrations or poke-through termination devices as well as to firestops alone
(material with no penetrations). These firestop systems are intended for use
in openings in fire resistive wall and floor assemblies which are evaluated in
accordance with CAN4-S101M, Standard Methods of Fire Endurance…