Uninterruptible power systems (UPS) - Part 1: Safety requirements
IEC 62040-1:2017 applies to movable, stationary, fixed or built-in UPS for use in low-voltage distribution systems and that are intended to be installed in an area accessible by an ordinary person or in a restricted access area as applicable, that deliver fixed frequency AC output voltage with port voltages not exceeding 1 000 V AC or 1 500 V DC and that include an energy storage device. It…
Multimedia home network configuration - Basic reference model - Part 2: Operational model
IEC 62608-2:2017 specifies the operational model for home network configuration. In the home network, various CE devices that have distinctive functions are connected on a shared network. However, there is no manager in the home network. Thus, a standardized network management procedure is required for suitable network operation. This document specifies the management procedure as sequences. The…
Digital living network alliance (DLNA) home networked device interoperability guidelines - Part 1-2:...
IEC 62481-1-2:2017 introduces a number of device classes to identify specific roles that connected endpoints implement in the network. Devices can act as content sources (e.g., Digital Media Servers, Push Controllers), and as content sinks (Digital Media Renderers or Digital Media Players). This document addresses this issue and, specifically, it describes a device class for an Extended Digital…
Software Cybersecurity for Network-Connectable Products, Part 1: General Requirements
1 Scope
1.1 This standard applies to network-connectable products that shall be evaluated and tested for
vulnerabilities, software weaknesses and malware.
1.2 This standard describes:
a) Requirements regarding the software developer (vendor or other supply chain member) risk
management process for their product.
b) Methods by which a product shall be evaluated and tested for the presence of…
Medical gas pipeline systems — Part 1: Pipelines for medical gases, medical vacuum, medical support ...
1.1
This Standard specifies safety requirements for pipelines for medical gases, medical vacuum, medical
support gases, and anaesthetic gas scavenging systems in health care facilities, both public and private.
It applies to all facilities providing health care services, regardless of type, size, location, or range of
services, including, but not limited to
a) acute care hospitals;
b) in-…
Standard for Containment Sumps, Sump Fittings, and Accessories for Flammable and Combustible Liquids...
This Standard sets forth the minimum requirements for containment sumps, and associated sump
fittings and accessories (products) intended for below- or at-grade use as an enclosure for housing of, and access to, underground piping, connector piping, and other fueling system components (such as pumps, valves, sensors, wiring, etc.) in addition to temporary containment of typical liquid fuels as…
Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential per...
IEC 60601-1:2005+AMD1:2012, 1.1 is replaced by:
This part of ISO 80601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a VENTILATOR in
combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT:
— intended for use in the HOME HEALTHCARE ENVIRONMENT;
— intended for use by a LAY OPERATOR;
— intended for use with PATIENTS who are dependent on mechanical ventilation for…
General requirements for pressure-retaining systems and components in CANDU nuclear power plants/Mat...
1.1
This Standard specifies the technical requirements for the design, procurement, fabrication, installation, modification, repair, replacement, testing, examination, and inspection of, and other work related to, pressure-retaining systems, components, and supports over the service life of a CANDU nuclear power plant.
1.2
This Standard applies to all pressure-retaining systems, including…
Thermal performance of curtain walling — Calculation of thermal transmittance
ISO 12631:2017 specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames.
The calculation includes:
- different types of glazing, e.g. glass or plastic; single or multiple glazing; with or without low emissivity coating; with cavities filled with air or other gases;
- frames (of any material…
Household and similar electrical appliances - Safety - Part 2-64: Particular requirements for commer...
IEC 60335-2-64:2002+A1:2007+A2:2017 deals with the safety of electrically operated commercial kitchen machines not intended for household use. The rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances. Appliances within the scope of this standard are typically used in restaurants, canteens, hospitals and…