Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halo...
IEC 60754-1:2011+A1:2019 specifies the apparatus and procedure for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers and compounds containing halogenated additives taken from electric or optical fibre cable constructions. The method specified in this standard is intended for the testing of…
Electromechanical elementary relays - Part 1: General and safety requirements
IEC 61810-1:2015 applies to electromechanical elementary relays (non-specified time all-or-nothing relays) for incorporation into low voltage equipment (circuits up to 1 000 V alternate current or 1 500 V direct current). It defines the basic functional and safety requirements and safety-related aspects for applications in all areas of electrical engineering or electronics, such as: general…
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and...
IEC 61034-2:2005+A1:2013+A2:2019 provides details of the test procedure to be employed for the measurement of the density of smoke emitted from cables burning under defined conditions. It describes the means of preparing and assembling cables for test, the method of burning the cables, and gives recommended requirements for evaluating test results. The principal changes with respect to the…
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential per...
IEC 60601-2-22:2019 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60601-2-22:2019 applies to the Basic Safety and Essential Performance of laser equipment for surgical,…
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential per...
IEC 60601-2-22:2019 applies to the Basic Safety and Essential Performance of laser equipment for surgical, therapeutic, medical diagnostic, cosmetic or veterinary applications, intended for use on humans or animals, classified as Laser Product of Class 1C where the Enclosed Laser is of Class 3B or 4, or Class 3B, or Class 4. Medical Electrical Equipment or Medical Electrical Systems which…
Footwear — Critical substances potentially present in footwear and footwear components — Determinati...
This document specifies a method for the determination of the content of 12 kinds of Nitrosamines (see Annex A) in footwear and footwear components by using solvent extraction and Gas chromatography with mass selective detector (GC-MS).
This document is applicable to rubber in footwear materials.
NOTE ISO/TR 16178 defines which materials are concerned by this
Household and similar electrical appliances - Safety - Part 2-90: Particular requirements for commer...
IEC 60335-2-90:2015+A1:2019 deals with
- the safety of microwave ovens with a cavity door intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances;
- the safety of combination microwave ovens with a cavity door, the requirements for which are contained in Annex AA;
- the safety of…
Gas cylinders — Valve protection caps and guards — Design, construction and tests
This document specifies the requirements for valve protection caps and valve guards used on cylinders for liquefied, dissolved or compressed gases.
Valve protection caps and valve guards are some of the options available to protect cylinder valves, including valves with integral pressure regulators (VIPRs) during transport.
This document is applicable to valve protection caps and valve guards…
Household and similar electrical appliances - Safety - Part 2-90: Particular requirements for commer...
IEC 60335-2-90:2015+A1:2019 deals with
- the safety of microwave ovens with a cavity door intended for commercial use, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral and 480 V for other appliances;
- the safety of combination microwave ovens with a cavity door, the requirements for which are contained in Annex AA;
- the safety…