This is a searchable PDF.
1.1 Scope
1.1.1 This standard applies to newly produced outdoor cooking gas appliances (see Part IV, Definitions), constructed entirely of new, unused parts and materials. Outdoor cooking gas appliances submitted for examination under this standard shall be classified as either portable or stationary.
1.1.2 This standard does not apply to outdoor…
1. Scope
1.1 These requirements apply to the following stationary equipment for use in nonhazardous locations rated 7200 V or less, single- or 3-phase, and remote control assemblies for such equipment.
(a) Heat pumps, for heating and cooling with or without factory or field-installed electric resistance heaters, or hot water or steam heating coils.
(b) Air conditioners for cooling…
1. Domaine d'application
1.1 Cette norme s'applique au matériel fixe de tension nominale, monophasée ou triphasée, inférieure ou égale à 7200 V, destiné à être utilisé dans des emplacements non dangereux, qui sont énumérés ci-dessous ainsi qu'aux commandes à distance qui s'y rattachent:
(a) pompes à chaleur destinées au chauffage et au refroidissement, avec ou…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers, microwave coupled plasma spectrometers, and mass spectrometers, all with thermal atomization and ionization (including tubing and connectors which are…
Gas mixers for medical use — Stand-alone gas mixers
Gives requirements for the performance and safety of stand-alone gas mixers intended for medical use and for connection to a medical gas supply system.
Connectors for frequencies below 3 MHz for use with printed boards - Part 2: Detail specification fo...
IEC 60603-2:1995 applies to groups of related connectors for use with printed boards. They range from connectors with high contact density for low-voltage applications (Styles B and C) to connectors for heavy currents and high voltages having fewer contacts (Styles D, E, F, G and H). It also applies to Style M two-part connectors supplied in alternative versions having 2, 4 or 6 holes for fitting…
Connecting devices - Safety requirements for screw-type and screwless-type clamping units for electr...
Applies for the connection of electrical copper conductors, rigid stranded and/or flexible, having a cross-sectional area from 35 mm2 flexible up to and including 300 mm2 and equivalent AWG/kcmil sizes with a rated voltage not exceeding 1 000 V a.c. and a frequency up to and including 1 000 Hz, and 1 500 V d.c. Has the status of a group safety publication in accordance with IEC Guide 104.
Equipment for general lighting purposes - EMC immunity requirements
Applies to lighting equipment which is within the scope of IEC technical committee 34, such as lamps, auxiliaries and lunminaires, intended either for connecting to a low voltage electricity supply or for battery operation.
Aluminium structures — Material and design — Ultimate limit state under static loading
This Technical Report provides design expressions to determine the characteristic values for the ultimate resistances of components and connections of aluminium structures which are subjected to known static forces.