Hydraulic fluid power — Determination of pressure ripple levels generated in systems and components ...
ISO 10767-1:2015 establishes a test procedure for measuring the source flow ripple and source impedance of positive-displacement hydraulic pumps. It is applicable to all types of positive-displacement pumps operating under steady-state conditions, irrespective of size, provided that the pumping frequency is in the range from 50 Hz to 400Hz.
Source flow ripple causes fluid borne vibration (…
Transmissions hydrauliques — Détermination des niveaux d'onde de pression engendrés dans les ci...
L'ISO 10767-1-1:2015 établit un mode opératoire d'essai pour le mesurage de l'onde d'écoulement de la source et de l'impédance de la source des pompes hydrauliques volumétriques. Elle s'applique à tous les types de pompes volumétriques fonctionnant dans des conditions de régime permanent, quelle que soit leur taille, à condition que la fréquence de pompage soit…
Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing require...
IEC/IEEE 60079-30-1:2015 specifies general and testing requirements for electrical resistance trace heaters for application in explosive atmospheres with the exclusion of those for EPL Ga and Da. This standard covers trace heaters that comprise either factory or field (work-site) assembled units, and which may be series trace heaters, parallel trace heaters, trace heater pads, or trace heater…
Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for desig...
IEC/IEEE 60079-30-2:2015 provides guidance for the application of electrical resistance trace heating systems in areas where explosive atmospheres may be present, with the exclusion of those classified as requiring EPL Ga/Da (traditional relationship to Zone 0 and Zone 20 respectively). This standard also provides guidance for explosive atmospheres incorporating the Division method of area…
Vitreous and porcelain enamels — High voltage test
ISO 2746:2015 describes two test methods of high voltage testing:
- Test A is used to detect and locate defects in vitreous and porcelain enamels;
- Test B is used to detect and locate defects and weak spots in vitreous and porcelain enamels.
The tests are performed using DC or pulsed DC high voltage.
The tests are applicable to dry surfaces of enamel coatings. In the case of moist…
Information technology — Business operational view — Part 9: Business transaction traceability frame...
ISO/IEC 15944-9:2015 presents a framework consisting of several models, including a reference model, a model of concepts, a content model, an information model, as well as rules, templates and other technical specifications for traceability requirements based on internal or external constraints as applicable to a business transaction. The internal constraints are imposed in Open-edi due to mutual…
Le domaine d'application général de l'ISO/TS 19299:2015 consiste à fournir un cadre de sécurité de l'information pour l'ensemble des entités organisationnelles et techniques d'un plan de perception du télépéage (EFC), et plus particulièrement pour les interfaces entre elles, sur la base de l'architecture système définie dans l'ISO 17573. Le cadre de sécurité…
ISO 2746:2015 décrit deux méthodes d'essai sous haute tension:
- l'essai A sert à détecter et à localiser les défauts dans les émaux vitrifiés;
- l'essai B sert à détecter et à localiser les défauts et les points faibles dans les émaux vitrifiés.
Les essais sont réalisés sous haute tension en courant continu ou en courant continu pulsé.
Les essais sont effectués sur les…