Rechercher

Select view block
ORD Data
Affiner les résultats
Nom de l'autorité
Organisme de certification
Code de statut
Date de publication

De

à

Affichage 25 - 30 de 404
Polypropylene Push Fit Drain, Waste, and Vent (DWV) Fittings
This Standard covers reversible 1-1/4 and 1-1/2? NTS Polypropylene push fit drain, waste, and vent fittings intended for quick assembly of PVC and PP DWV pipe and fittings applications, and specifies requirements for materials, physical characteristics, performance testing, and markings.
Status :
Valide
Date de publication :
1969-12-30
Organisme de certification :
IAPMO Research and Testing, Inc.
Interim Energy Efficiency Certification and Verification Requirements for Commercial Refrigeration E...
Published under Certification Informs Verification Service Announcement No 79, Ref No: I18-117 This Technical Information Letter (T.I.L.) has been prepared to amend CAN/CSA C657-15 to add integrated average temperature for refrigerator-freezer with transparent door and harmonized total display area calculation method with methodology outlined by United States Department of Energy (U.S. DOE).
Status :
Valide
Date de publication :
2000-07-01
Organisme de certification :
CSA Group Testing & Certification Inc.
Interim Certification Requirements for Self Ballasted Tubular LED (TLED) Type A Lamps
Status :
Rescinded
Date de publication :
1969-12-30
Organisme de certification :
CSA Group Testing & Certification Inc.
Folded poly (vinyl chloride) (PVC) pipe for existing sewer rehabilitation.
ORD would cover requirements and test methods for folded PVC liners for existing sewer and conduit rehabilitation
Status :
Valide
Date de publication :
1969-12-30
Organisme de certification :
CSA Group Testing & Certification Inc.
In-ground Boxes
These requirements cover in-ground boxes with integral electrical enclosure(s) for housing wiring devices connected to a branch circuit. The unit is intended to be installed outdoors and in the ground. The unit provides access to one or more receptacle outlets and is intended to be installed in accordance with NFPA 70, National Electrical Code, CSA C22.1, Canadian Electrical Code, Part I, Safety…
Status :
Valide
Date de publication :
1969-12-30
Organisme de certification :
Underwriters' Laboratories of Canada
Interim Certification Requirements for Pullout Switches
This Technical Information Letter (T.I.L.) provides requirements for the electrical safety of non-enclosed and enclosed pullout switches of the detachable type, rated up to 600 V and 400A.
Status :
Valide
Date de publication :
1969-12-30
Organisme de certification :